Persistent Link:
http://hdl.handle.net/10150/609630
Title:
Magnetic Tape Synchronizer/Controller
Author:
Schoeck, K. O.; Martin, S. W.
Affiliation:
Vandenberg Air Force Base; Datatape
Issue Date:
1976-09
Rights:
Copyright © International Foundation for Telemetering
Collection Information:
Proceedings from the International Telemetering Conference are made available by the International Foundation for Telemetering and the University of Arizona Libraries. Visit http://www.telemetry.org/index.php/contact-us if you have questions about items in this collection.
Publisher:
International Foundation for Telemetering
Journal:
International Telemetering Conference Proceedings
Abstract:
A method has been developed to time synchronize multiple wideband magnetic tape recorder/reproducers to allow realtime data merging of tapes from various tracking stations. The system operates using either IRIG A and/or IRIG B time codes, and maintains synchronization within 10 microseconds using IRIG A and 50 microseconds using IRIG B.
Sponsors:
International Foundation for Telemetering
ISSN:
0884-5123; 0074-9079
Additional Links:
http://www.telemetry.org/

Full metadata record

DC FieldValue Language
dc.language.isoen_USen
dc.titleMagnetic Tape Synchronizer/Controlleren_US
dc.contributor.authorSchoeck, K. O.en
dc.contributor.authorMartin, S. W.en
dc.contributor.departmentVandenberg Air Force Baseen
dc.contributor.departmentDatatapeen
dc.date.issued1976-09-
dc.rightsCopyright © International Foundation for Telemeteringen
dc.description.collectioninformationProceedings from the International Telemetering Conference are made available by the International Foundation for Telemetering and the University of Arizona Libraries. Visit http://www.telemetry.org/index.php/contact-us if you have questions about items in this collection.en
dc.publisherInternational Foundation for Telemeteringen
dc.description.abstractA method has been developed to time synchronize multiple wideband magnetic tape recorder/reproducers to allow realtime data merging of tapes from various tracking stations. The system operates using either IRIG A and/or IRIG B time codes, and maintains synchronization within 10 microseconds using IRIG A and 50 microseconds using IRIG B.en
dc.description.sponsorshipInternational Foundation for Telemeteringen
dc.identifier.issn0884-5123-
dc.identifier.issn0074-9079-
dc.identifier.urihttp://hdl.handle.net/10150/609630-
dc.identifier.journalInternational Telemetering Conference Proceedingsen
dc.typetexten
dc.typeProceedingsen
dc.relation.urlhttp://www.telemetry.org/en
All Items in UA Campus Repository are protected by copyright, with all rights reserved, unless otherwise indicated.