Persistent Link:
http://hdl.handle.net/10150/609351
Title:
A Telemetry Link for an Earth Penetrator
Author:
Caffey, Thurlow W. H.
Affiliation:
Sandia Laboratories
Issue Date:
1975-10
Rights:
Copyright © International Foundation for Telemetering
Collection Information:
Proceedings from the International Telemetering Conference are made available by the International Foundation for Telemetering and the University of Arizona Libraries. Visit http://www.telemetry.org/index.php/contact-us if you have questions about items in this collection.
Publisher:
International Foundation for Telemetering
Journal:
International Telemetering Conference Proceedings
Abstract:
The design and field-testing of a telemetry link to send signals to the surface of the earth from an earth penetrator are described. The link uses a PCM/FM format at a frequency of 10.5 kHz, dissipates 8 watts, and fits within a cylinder with an inside diameter of 100 mm. A bit error rate of less than 10⁻⁵ was achieved from a depth of 52 meters at a bit rate of 10³ bits per second.
Sponsors:
International Foundation for Telemetering
ISSN:
0884-5123; 0074-9079
Additional Links:
http://www.telemetry.org/

Full metadata record

DC FieldValue Language
dc.language.isoen_USen
dc.titleA Telemetry Link for an Earth Penetratoren_US
dc.contributor.authorCaffey, Thurlow W. H.en
dc.contributor.departmentSandia Laboratoriesen
dc.date.issued1975-10en
dc.rightsCopyright © International Foundation for Telemeteringen
dc.description.collectioninformationProceedings from the International Telemetering Conference are made available by the International Foundation for Telemetering and the University of Arizona Libraries. Visit http://www.telemetry.org/index.php/contact-us if you have questions about items in this collection.en
dc.publisherInternational Foundation for Telemeteringen
dc.description.abstractThe design and field-testing of a telemetry link to send signals to the surface of the earth from an earth penetrator are described. The link uses a PCM/FM format at a frequency of 10.5 kHz, dissipates 8 watts, and fits within a cylinder with an inside diameter of 100 mm. A bit error rate of less than 10⁻⁵ was achieved from a depth of 52 meters at a bit rate of 10³ bits per second.en
dc.description.sponsorshipInternational Foundation for Telemeteringen
dc.identifier.issn0884-5123en
dc.identifier.issn0074-9079en
dc.identifier.urihttp://hdl.handle.net/10150/609351en
dc.identifier.journalInternational Telemetering Conference Proceedingsen
dc.typetexten
dc.typeProceedingsen
dc.relation.urlhttp://www.telemetry.org/en
All Items in UA Campus Repository are protected by copyright, with all rights reserved, unless otherwise indicated.