RESTORE PCM TELEMETRY SIGNAL WAVEFORM BY MAKING USE OF MULTI-SAMPLE RATE INTERPOLATION TECHNOLOGY
Author
Peng, SongAffiliation
China Luoyang Optoelectro Technology Development CenterIssue Date
1999-10
Metadata
Show full item recordRights
Copyright © International Foundation for TelemeteringCollection Information
Proceedings from the International Telemetering Conference are made available by the International Foundation for Telemetering and the University of Arizona Libraries. Visit http://www.telemetry.org/index.php/contact-us if you have questions about items in this collection.Abstract
There are two misty understandings about PCM telemetry system in conventional concept: Waveform can not be restored accurately; to be restored accurately, a measured signal must be sampled at a higher sample rate. This paper discusses that by making use of multi-sample rate DSP technology, the sample rate of a measured signal can be reduced in transmission equipment, or system precision can be retained even if the performance of low pass filter declined.Sponsors
International Foundation for TelemeteringISSN