Abstract:
Current legacy acquisition systems such as the Advanced Airborne Test Instrumentation System (AATIS) are custom-built to each individual application with unique sensors and data modules. Replacing, adding, or subtracting sensors requires the system to be removed from service for days, weeks, or even months. This is a result of having to route special wires to each sensor and reprogramming the system with sensor information, calibration data, etc. AR sensor information must be contained in the main system since these systems do not have intelligence at the sensor level. If sensors were to contain information in their own IEEE 1451-compliant transducer electronic data sheet (TEDS), the main system would no longer have to be reprogrammed with this information. This information could then be obtained directly from the sensors when they are inserted into the system. A plug-n-play capability is being added to the system with the development of a standard interface to the system control unit (SCU). This interface, called a Multi-Network Capable Applications Processor (Multi-NCAP), will interface IEEE 1451-compliant smart transducer interface modules (STIMs) to the SCU in the AATIS as well as other legacy systems. With this development, maintenance and new configuration times for the AATIS and other legacy systems will be significantly reduced.
Keywords:
Smart Transducers; IEEE 1451; AATIS; Data Acquisition; TEDS; STIM; NCAP
Sponsors:
International Foundation for Telemetering
ISSN:
0884-5123; 0074-9079
Additional Links:
http://www.telemetry.org/

Full metadata record

DC FieldValue Language
dc.language.isoen_USen
dc.titleAPPLYING IEEE 1451 STANDARD TO AATISen_US
dc.contributor.authorSinclair, Roberten
dc.contributor.authorJones, Charles H.en
dc.contributor.departmentNonvolatile Electronics, Inc.en
dc.contributor.departmentEdwards Air Force Baseen
dc.date.issued2001-10en
dc.rightsCopyright © International Foundation for Telemeteringen
dc.description.collectioninformationProceedings from the International Telemetering Conference are made available by the International Foundation for Telemetering and the University of Arizona Libraries. Visit http://www.telemetry.org/index.php/contact-us if you have questions about items in this collection.en
dc.publisherInternational Foundation for Telemeteringen
dc.description.abstractCurrent legacy acquisition systems such as the Advanced Airborne Test Instrumentation System (AATIS) are custom-built to each individual application with unique sensors and data modules. Replacing, adding, or subtracting sensors requires the system to be removed from service for days, weeks, or even months. This is a result of having to route special wires to each sensor and reprogramming the system with sensor information, calibration data, etc. AR sensor information must be contained in the main system since these systems do not have intelligence at the sensor level. If sensors were to contain information in their own IEEE 1451-compliant transducer electronic data sheet (TEDS), the main system would no longer have to be reprogrammed with this information. This information could then be obtained directly from the sensors when they are inserted into the system. A plug-n-play capability is being added to the system with the development of a standard interface to the system control unit (SCU). This interface, called a Multi-Network Capable Applications Processor (Multi-NCAP), will interface IEEE 1451-compliant smart transducer interface modules (STIMs) to the SCU in the AATIS as well as other legacy systems. With this development, maintenance and new configuration times for the AATIS and other legacy systems will be significantly reduced.en
dc.subjectSmart Transducersen
dc.subjectIEEE 1451en
dc.subjectAATISen
dc.subjectData Acquisitionen
dc.subjectTEDSen
dc.subjectSTIMen
dc.subjectNCAPen
dc.description.sponsorshipInternational Foundation for Telemeteringen
dc.identifier.issn0884-5123en
dc.identifier.issn0074-9079en
dc.identifier.urihttp://hdl.handle.net/10150/606467en
dc.identifier.journalInternational Telemetering Conference Proceedingsen
dc.typetexten
dc.typeProceedingsen
dc.relation.urlhttp://www.telemetry.org/en
All Items in UA Campus Repository are protected by copyright, with all rights reserved, unless otherwise indicated.