Persistent Link:
http://hdl.handle.net/10150/577490
Title:
PCM Backfill: Providing PCM to the Control Room Without Dropouts
Author:
Morgan, Jon; Jones, Charles H.
Affiliation:
Edwards Air Force Base
Issue Date:
2014-10
Rights:
Copyright © held by the author; distribution rights International Foundation for Telemetering
Collection Information:
Proceedings from the International Telemetering Conference are made available by the International Foundation for Telemetering and the University of Arizona Libraries. Visit http://www.telemetry.org/index.php/contact-us if you have questions about items in this collection.
Publisher:
International Foundation for Telemetering
Journal:
International Telemetering Conference Proceedings
Abstract:
One of the initial control room capabilities to be demonstrated by iNET program is the ability to provide data displays in the control room that do not contain data dropouts. This concept is called PCM Backfill where PCM data is both transmitted via traditional SST and recorded onboard via an iNET compatible recorder. When data dropouts occur, data requests are made over the telemetry network to the recorder for the missing portions of the PCM data stream. The retrieved data is sent over the telemetry network to the backfill application and ultimately delivered to a pristine data display. The integration of traditional SST and the PCM Backfill capability provides both real-time safety of flight data side-by-side with pristine data suitable for advanced analysis.
Keywords:
Pulse Code Modulation (PCM); network; wireless; telemetry; data processing; Telemetry Network System (TmNS); integrated Network Enhanced Telemetry (iNET); Transmission Control Protocol (TCP); recorder; Enhanced Query Data Recorder (EQDR)
Sponsors:
International Foundation for Telemetering
ISSN:
0884-5123; 0074-9079
Additional Links:
http://www.telemetry.org/

Full metadata record

DC FieldValue Language
dc.language.isoen_USen
dc.titlePCM Backfill: Providing PCM to the Control Room Without Dropoutsen_US
dc.contributor.authorMorgan, Jonen
dc.contributor.authorJones, Charles H.en
dc.contributor.departmentEdwards Air Force Baseen
dc.date.issued2014-10en
dc.rightsCopyright © held by the author; distribution rights International Foundation for Telemeteringen_US
dc.description.collectioninformationProceedings from the International Telemetering Conference are made available by the International Foundation for Telemetering and the University of Arizona Libraries. Visit http://www.telemetry.org/index.php/contact-us if you have questions about items in this collection.en_US
dc.publisherInternational Foundation for Telemeteringen
dc.description.abstractOne of the initial control room capabilities to be demonstrated by iNET program is the ability to provide data displays in the control room that do not contain data dropouts. This concept is called PCM Backfill where PCM data is both transmitted via traditional SST and recorded onboard via an iNET compatible recorder. When data dropouts occur, data requests are made over the telemetry network to the recorder for the missing portions of the PCM data stream. The retrieved data is sent over the telemetry network to the backfill application and ultimately delivered to a pristine data display. The integration of traditional SST and the PCM Backfill capability provides both real-time safety of flight data side-by-side with pristine data suitable for advanced analysis.en
dc.subjectPulse Code Modulation (PCM)en
dc.subjectnetworken
dc.subjectwirelessen
dc.subjecttelemetryen
dc.subjectdata processingen
dc.subjectTelemetry Network System (TmNS)en
dc.subjectintegrated Network Enhanced Telemetry (iNET)en
dc.subjectTransmission Control Protocol (TCP)en
dc.subjectrecorderen
dc.subjectEnhanced Query Data Recorder (EQDR)en
dc.description.sponsorshipInternational Foundation for Telemeteringen
dc.identifier.issn0884-5123en
dc.identifier.issn0074-9079en
dc.identifier.urihttp://hdl.handle.net/10150/577490en
dc.identifier.journalInternational Telemetering Conference Proceedingsen
dc.typetexten
dc.typeProceedingsen
dc.relation.urlhttp://www.telemetry.org/en
All Items in UA Campus Repository are protected by copyright, with all rights reserved, unless otherwise indicated.