Persistent Link:
http://hdl.handle.net/10150/300990
Title:
Chemical Oxygen Demand of the Antitranspirant, Folicote
Author:
Garrett, R. H.; Kynard, B. E.
Affiliation:
School of Renewable Natural Resources, The University of Arizona, Tucson
Issue Date:
16-Apr-1977
Rights:
Copyright ©, where appropriate, is held by the author.
Collection Information:
This article is part of the Hydrology and Water Resources in Arizona and the Southwest collections. Digital access to this material is made possible by the Arizona-Nevada Academy of Science and the University of Arizona Libraries. For more information about items in this collection, contact anashydrology@gmail.com.
Publisher:
Arizona-Nevada Academy of Science
Journal:
Hydrology and Water Resources in Arizona and the Southwest
Abstract:
During a standard bioassay using fish and the antitranspirant Folicote, a significant deoxygenation of the water was observed. Oxygen demand tests without fish using distilled water indicated that at 25 °C Folicote reduced D.O. from saturation (8 ppm) to 0.1 ppm within 60 hrs. Oxygen consumptive qualities of Folicote should be taken under consideration during actual field applications.
Keywords:
Hydrology -- Arizona.; Water resources development -- Arizona.; Hydrology -- Southwestern states.; Water resources development -- Southwestern states.
ISSN:
0272-6106

Full metadata record

DC FieldValue Language
dc.language.isoen_USen_US
dc.titleChemical Oxygen Demand of the Antitranspirant, Folicoteen_US
dc.contributor.authorGarrett, R. H.en_US
dc.contributor.authorKynard, B. E.en_US
dc.contributor.departmentSchool of Renewable Natural Resources, The University of Arizona, Tucsonen_US
dc.date.issued1977-04-16-
dc.rightsCopyright ©, where appropriate, is held by the author.en_US
dc.description.collectioninformationThis article is part of the Hydrology and Water Resources in Arizona and the Southwest collections. Digital access to this material is made possible by the Arizona-Nevada Academy of Science and the University of Arizona Libraries. For more information about items in this collection, contact anashydrology@gmail.com.en_US
dc.publisherArizona-Nevada Academy of Scienceen_US
dc.identifier.journalHydrology and Water Resources in Arizona and the Southwesten_US
dc.description.abstractDuring a standard bioassay using fish and the antitranspirant Folicote, a significant deoxygenation of the water was observed. Oxygen demand tests without fish using distilled water indicated that at 25 °C Folicote reduced D.O. from saturation (8 ppm) to 0.1 ppm within 60 hrs. Oxygen consumptive qualities of Folicote should be taken under consideration during actual field applications.en_US
dc.subjectHydrology -- Arizona.en_US
dc.subjectWater resources development -- Arizona.en_US
dc.subjectHydrology -- Southwestern states.en_US
dc.subjectWater resources development -- Southwestern states.en_US
dc.identifier.issn0272-6106-
dc.identifier.urihttp://hdl.handle.net/10150/300990-
dc.identifier.journalHydrology and Water Resources in Arizona and the Southwesten_US
dc.typetexten_US
dc.typeProceedingsen_US
All Items in UA Campus Repository are protected by copyright, with all rights reserved, unless otherwise indicated.