Abstract:
This study uses Monte Carlo simulation to examine the performance of a variable frequency sampling cumulative sum control chart scheme for controlling the mean of a normal process. The study compares the performance of the method with that of a standard fixed interval sampling cumulative sum control chart scheme. The results indicate that the variable frequency sampling cumulative sum control chart scheme is superior to the standard cumulative sum control chart scheme in detecting a small to moderate shift in the process mean.
Type:
text; Thesis-Reproduction (electronic)
Keywords:
Process control.; Quality control -- Charts, diagrams, etc.
Degree Name:
M.S.
Degree Level:
masters
Degree Program:
Graduate College; Systems and Industrial Engineering
Degree Grantor:
University of Arizona

Full metadata record

DC FieldValue Language
dc.language.isoen_USen_US
dc.titleA VARIABLE SAMPLING FREQUENCY CUMULATIVE SUM CONTROL CHART SCHEMEen_US
dc.creatorMyslicki, Stefan Leopold, 1953-en_US
dc.contributor.authorMyslicki, Stefan Leopold, 1953-en_US
dc.date.issued1987en_US
dc.publisherThe University of Arizona.en_US
dc.rightsCopyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author.en_US
dc.description.abstractThis study uses Monte Carlo simulation to examine the performance of a variable frequency sampling cumulative sum control chart scheme for controlling the mean of a normal process. The study compares the performance of the method with that of a standard fixed interval sampling cumulative sum control chart scheme. The results indicate that the variable frequency sampling cumulative sum control chart scheme is superior to the standard cumulative sum control chart scheme in detecting a small to moderate shift in the process mean.en_US
dc.typetexten_US
dc.typeThesis-Reproduction (electronic)en_US
dc.subjectProcess control.en_US
dc.subjectQuality control -- Charts, diagrams, etc.en_US
thesis.degree.nameM.S.en_US
thesis.degree.levelmastersen_US
thesis.degree.disciplineGraduate Collegeen_US
thesis.degree.disciplineSystems and Industrial Engineeringen_US
thesis.degree.grantorUniversity of Arizonaen_US
dc.identifier.proquest1331460en_US
dc.identifier.oclc18003535en_US
dc.identifier.bibrecord.b16440651en_US
All Items in UA Campus Repository are protected by copyright, with all rights reserved, unless otherwise indicated.