Hybrid Nanoparticles for Enhanced Sensitivity in Biological Labeling and Biomolecular Sensing

Persistent Link:
http://hdl.handle.net/10150/202514
Title:
Hybrid Nanoparticles for Enhanced Sensitivity in Biological Labeling and Biomolecular Sensing
Author:
Janczak, Colleen
Issue Date:
2011
Publisher:
The University of Arizona.
Rights:
Copyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author.
Abstract:
Nanoparticles (nPs) demonstrate significant advantages over other sensor and marker technologies. The most useful optical nanosensor and label platform for biological samples would be non-toxic, hydrophilic, resistant to non-specific protein interactions and degradation over time or under harsh conditions, highly retentive of entrapped components, and easily functionalized for target specificity. The work described here is part of an investigation into the fabrication and application of polyacrylamide, polyacrylamide/silica hybrid, and polystyrene-core silica-shell nPs. Polyacrylamide (PA) nP nitric oxide (NO) sensors were made by co-entrapping 4, 5-diaminofluorescein (DAF-2) and Texas Red dextran in 60 nm PAnPs. Sensors were used to measure NO produced by a diazeniumdiolate NO donor in solution, and have a response time of 30 seconds or less. Entrapped DAF-2 was protected from non-specific interactions with bovine serum albumin (BSA). Sensor response to NO in FBS solutions was reduced compared to buffer, although improvement over free dyes was observed. The sensors were applied to J477A.1 macrophages as well as a HT1080 cell line (HTRiNOS) in preliminary studies for measuring intracellular NO production. Polyacrylamide/silica hybrid nPs were fabricated and nP architecture was evaluated by transmission electron microscopy. Isopycnic centrifugation of nP samples indicates that the hybrid nPs have a density between 1.70 and 1.76 g/cm³. Silica in the hybrid nPs was covalently labeled with Texas Red, suggesting that the hybrid nPs may be used as ratiometric or possibly multiplexed sensors. Hybrid nPs coated with 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC) exhibit reduced adsorption of TRITC-BSA compared to uncoated hybrid nPs. Hybrid nP pH sensors were prepared and responded reproducibly and reversibly to changes in pH, nominally from pH 6.0 to 8.0. Core-shell nPs for scintillation proximity assay (SPA) were fabricated by entrapping the scintillants p-terphenyl and 4-bis(4-methyl-5-phenyl-2oxyzolyl)benzene in polystyrene, onto which silica shells were subsequently added. Core-shell nPs were found to have a scintillation response similar to that of shell-less polystyrene cores, indicating that the presence of the silica shells does not reduce scintillation efficiency. Preliminary studies using core-shell nPS for biotin-streptavidin binding SPA do not indicate an enhancement in scintillation efficiency, although this may be due to high nP:radiolabeled analyte ratios.
Type:
text; Electronic Dissertation
Keywords:
sensor; Chemistry; biolabel; nanoparticle
Degree Name:
Ph.D.
Degree Level:
doctoral
Degree Program:
Graduate College; Chemistry
Degree Grantor:
University of Arizona
Advisor:
Aspinwall, Craig A.

Full metadata record

DC FieldValue Language
dc.language.isoenen_US
dc.titleHybrid Nanoparticles for Enhanced Sensitivity in Biological Labeling and Biomolecular Sensingen_US
dc.creatorJanczak, Colleenen_US
dc.contributor.authorJanczak, Colleenen_US
dc.date.issued2011-
dc.publisherThe University of Arizona.en_US
dc.rightsCopyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author.en_US
dc.description.abstractNanoparticles (nPs) demonstrate significant advantages over other sensor and marker technologies. The most useful optical nanosensor and label platform for biological samples would be non-toxic, hydrophilic, resistant to non-specific protein interactions and degradation over time or under harsh conditions, highly retentive of entrapped components, and easily functionalized for target specificity. The work described here is part of an investigation into the fabrication and application of polyacrylamide, polyacrylamide/silica hybrid, and polystyrene-core silica-shell nPs. Polyacrylamide (PA) nP nitric oxide (NO) sensors were made by co-entrapping 4, 5-diaminofluorescein (DAF-2) and Texas Red dextran in 60 nm PAnPs. Sensors were used to measure NO produced by a diazeniumdiolate NO donor in solution, and have a response time of 30 seconds or less. Entrapped DAF-2 was protected from non-specific interactions with bovine serum albumin (BSA). Sensor response to NO in FBS solutions was reduced compared to buffer, although improvement over free dyes was observed. The sensors were applied to J477A.1 macrophages as well as a HT1080 cell line (HTRiNOS) in preliminary studies for measuring intracellular NO production. Polyacrylamide/silica hybrid nPs were fabricated and nP architecture was evaluated by transmission electron microscopy. Isopycnic centrifugation of nP samples indicates that the hybrid nPs have a density between 1.70 and 1.76 g/cm³. Silica in the hybrid nPs was covalently labeled with Texas Red, suggesting that the hybrid nPs may be used as ratiometric or possibly multiplexed sensors. Hybrid nPs coated with 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC) exhibit reduced adsorption of TRITC-BSA compared to uncoated hybrid nPs. Hybrid nP pH sensors were prepared and responded reproducibly and reversibly to changes in pH, nominally from pH 6.0 to 8.0. Core-shell nPs for scintillation proximity assay (SPA) were fabricated by entrapping the scintillants p-terphenyl and 4-bis(4-methyl-5-phenyl-2oxyzolyl)benzene in polystyrene, onto which silica shells were subsequently added. Core-shell nPs were found to have a scintillation response similar to that of shell-less polystyrene cores, indicating that the presence of the silica shells does not reduce scintillation efficiency. Preliminary studies using core-shell nPS for biotin-streptavidin binding SPA do not indicate an enhancement in scintillation efficiency, although this may be due to high nP:radiolabeled analyte ratios.en_US
dc.typetexten_US
dc.typeElectronic Dissertationen_US
dc.subjectsensoren_US
dc.subjectChemistryen_US
dc.subjectbiolabelen_US
dc.subjectnanoparticleen_US
thesis.degree.namePh.D.en_US
thesis.degree.leveldoctoralen_US
thesis.degree.disciplineGraduate Collegeen_US
thesis.degree.disciplineChemistryen_US
thesis.degree.grantorUniversity of Arizonaen_US
dc.contributor.advisorAspinwall, Craig A.en_US
dc.contributor.committeememberDenton, M. Bonneren_US
dc.contributor.committeememberSaavedra, S. Scotten_US
dc.contributor.committeememberMiranda, Katrina M.en_US
dc.contributor.committeememberAspinwall, Craig A.en_US
All Items in UA Campus Repository are protected by copyright, with all rights reserved, unless otherwise indicated.