Hydrogeology of Butler Valley, Arizona : an artificial recharge and ground-water storage prefeasibility study

Persistent Link:
http://hdl.handle.net/10150/191861
Title:
Hydrogeology of Butler Valley, Arizona : an artificial recharge and ground-water storage prefeasibility study
Author:
Herndon, Roy Lee.
Issue Date:
1985
Publisher:
The University of Arizona.
Rights:
Copyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author.
Abstract:
A USGS finite-difference computer program was used to assess possible artificial recharge and recovery scenarios as part of a technical prefeasibility study of Butler Valley, Arizona. Available hydrogeologic data were compiled and analyzed to build a numerical groundwater flow model of the valley. Input data for the model were gathered from previous work as well as from field studies, including seismic refraction and gravity surveys and aquifer-pump tests performed as part of this investigation. The results of the computer simulations indicate that aquifer storage capacity increases in the upper portion of the basin due to a confined system in the lower portion. The computer model and available geologic data were used to identify potential locations in Butler Valley for artificial recharge operations. The areas along Cunningham Wash and the basin margins appear to be the most favorable for surficial water spreading. Artificial recharge using injection wells, though expensive, appears to be feasible from a hydrogeological standpoint, but chemical interactions between recharge water and native ground water could create undesireable well-screen clogging. Gravity and seismic refraction data collected at the outlet of Butler Valley indicate that ground-water outflow during recharge operations would be minimal because of a shallow subsurface bedrock aquiclude.
Type:
Thesis-Reproduction (electronic); text
LCSH Subjects:
Hydrology.; Groundwater -- Arizona -- Butler Valley.; Artificial groundwater recharge -- Arizona -- Butler Valley.
Degree Name:
M.S.
Degree Level:
masters
Degree Program:
Hydrology and Water Resources; Graduate College
Degree Grantor:
University of Arizona
Committee Chair:
Wilson, L. G.; Simpson, E. S.

Full metadata record

DC FieldValue Language
dc.language.isoenen_US
dc.titleHydrogeology of Butler Valley, Arizona : an artificial recharge and ground-water storage prefeasibility studyen_US
dc.creatorHerndon, Roy Lee.en_US
dc.contributor.authorHerndon, Roy Lee.en_US
dc.date.issued1985en_US
dc.publisherThe University of Arizona.en_US
dc.rightsCopyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author.en_US
dc.description.abstractA USGS finite-difference computer program was used to assess possible artificial recharge and recovery scenarios as part of a technical prefeasibility study of Butler Valley, Arizona. Available hydrogeologic data were compiled and analyzed to build a numerical groundwater flow model of the valley. Input data for the model were gathered from previous work as well as from field studies, including seismic refraction and gravity surveys and aquifer-pump tests performed as part of this investigation. The results of the computer simulations indicate that aquifer storage capacity increases in the upper portion of the basin due to a confined system in the lower portion. The computer model and available geologic data were used to identify potential locations in Butler Valley for artificial recharge operations. The areas along Cunningham Wash and the basin margins appear to be the most favorable for surficial water spreading. Artificial recharge using injection wells, though expensive, appears to be feasible from a hydrogeological standpoint, but chemical interactions between recharge water and native ground water could create undesireable well-screen clogging. Gravity and seismic refraction data collected at the outlet of Butler Valley indicate that ground-water outflow during recharge operations would be minimal because of a shallow subsurface bedrock aquiclude.en_US
dc.description.notehydrology collectionen_US
dc.typeThesis-Reproduction (electronic)en_US
dc.typetexten_US
dc.subject.lcshHydrology.en_US
dc.subject.lcshGroundwater -- Arizona -- Butler Valley.en_US
dc.subject.lcshArtificial groundwater recharge -- Arizona -- Butler Valley.en_US
thesis.degree.nameM.S.en_US
thesis.degree.levelmastersen_US
thesis.degree.disciplineHydrology and Water Resourcesen_US
thesis.degree.disciplineGraduate Collegeen_US
thesis.degree.grantorUniversity of Arizonaen_US
dc.contributor.chairWilson, L. G.en_US
dc.contributor.chairSimpson, E. S.en_US
dc.identifier.oclc213414596en_US
All Items in UA Campus Repository are protected by copyright, with all rights reserved, unless otherwise indicated.