Title:
ABSOLUTE RADIOMETRIC CALIBRATION OF A SPECTROPOLARIMETER.
Author:
CASTLE, KENNETH ROBERT.
Issue Date:
1985
Publisher:
The University of Arizona.
Rights:
Copyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author.
Abstract:
Two identical instruments have been developed for use in the field to make radiometric measurements. They have been described as spectropolarimeters because of their ability to make polarization measurements in narrow spectral passbands. They have been used as part of a NASA sponsored project to monitor the spectral and temporal response of the thematic mapper satellites. These satellites allow many natural and man-tended resources to be monitored over years of time, thus allowing their use to be planned for in the future. The dissertation discusses the design, fabrication, testing and absolute radiometric calibration of these spectropolarimeter instruments. The outstanding feature of these instruments are that they have been calibrated absolutely, for radiance measurements, to an accuracy of 2% - 3%, in the range of 400 nm to 1040 nm over selected spectral passbands. Previously, field measurements were considered good if they had an absolute accuracy of 10%, implying that the present accuracies are advancing the state-of-the-art for field instrument calibrations. These improved accuracies are the result of using two recently developed calibration standards, both of which use detector based methods. These standards are the Electrically Calibrated Pyroelectric Radiometer (ECPR), and the QED-100 quad detector. The end of the dissertation discusses the attempts made to verify that the accuracies claimed are indeed valid, and it is the author's belief that these accuracies have been verified completely.
Type:
text; Dissertation-Reproduction (electronic)
Keywords:
Ionization of gases.; Hydrogen-ion concentration.; Hydrogen -- Isotopes.
Degree Name:
Ph.D.
Degree Level:
doctoral
Degree Program:
Optical Sciences; Graduate College
Degree Grantor:
University of Arizona
Advisor:
Slater, Philip N.

Full metadata record

DC FieldValue Language
dc.language.isoenen_US
dc.titleABSOLUTE RADIOMETRIC CALIBRATION OF A SPECTROPOLARIMETER.en_US
dc.creatorCASTLE, KENNETH ROBERT.en_US
dc.contributor.authorCASTLE, KENNETH ROBERT.en_US
dc.date.issued1985en_US
dc.publisherThe University of Arizona.en_US
dc.rightsCopyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author.en_US
dc.description.abstractTwo identical instruments have been developed for use in the field to make radiometric measurements. They have been described as spectropolarimeters because of their ability to make polarization measurements in narrow spectral passbands. They have been used as part of a NASA sponsored project to monitor the spectral and temporal response of the thematic mapper satellites. These satellites allow many natural and man-tended resources to be monitored over years of time, thus allowing their use to be planned for in the future. The dissertation discusses the design, fabrication, testing and absolute radiometric calibration of these spectropolarimeter instruments. The outstanding feature of these instruments are that they have been calibrated absolutely, for radiance measurements, to an accuracy of 2% - 3%, in the range of 400 nm to 1040 nm over selected spectral passbands. Previously, field measurements were considered good if they had an absolute accuracy of 10%, implying that the present accuracies are advancing the state-of-the-art for field instrument calibrations. These improved accuracies are the result of using two recently developed calibration standards, both of which use detector based methods. These standards are the Electrically Calibrated Pyroelectric Radiometer (ECPR), and the QED-100 quad detector. The end of the dissertation discusses the attempts made to verify that the accuracies claimed are indeed valid, and it is the author's belief that these accuracies have been verified completely.en_US
dc.typetexten_US
dc.typeDissertation-Reproduction (electronic)en_US
dc.subjectIonization of gases.en_US
dc.subjectHydrogen-ion concentration.en_US
dc.subjectHydrogen -- Isotopes.en_US
thesis.degree.namePh.D.en_US
thesis.degree.leveldoctoralen_US
thesis.degree.disciplineOptical Sciencesen_US
thesis.degree.disciplineGraduate Collegeen_US
thesis.degree.grantorUniversity of Arizonaen_US
dc.contributor.advisorSlater, Philip N.en_US
dc.contributor.committeememberPalmer, James M.en_US
dc.identifier.proquest8525590en_US
dc.identifier.oclc696621163en_US
All Items in UA Campus Repository are protected by copyright, with all rights reserved, unless otherwise indicated.